Wiring diagram, multimeter test. Is 12V being supplied to the heating unit? Disconnect 12V wire to heater, check resistance of heating unit, specifically is it an open circuit at the heater?
I never bothered with the 12VDC setting and new fridges don't offer it.
replacing the selector switch looks like a big deal ($$$) so maybe a new refer is in order, but does it make sense to put a new refer in my 25 year old Lance model 300 Camper
Lance still installs three way (120 volt AC, 12-volt DC, and LP) fridges in their 2012 models. The refrigerator will automatically switch to 12-volts DC if 120-volts AC and LP gas is not present and if it is in the "Auto" (automatic) mode. My '03 Lance fridge operates the same way.
Bill
The old 122001 volt units were a joke even back then. . that is why all you see is gas and electric. . for the problems and cost it would be better to replace it with a modern one. .
I have a 2007 Dometic 2 way power fridge and I have learned a lot about it, but I'll complete that by saying I haven't learned ENOUGH about it.
These things are weird.
They (according to public theory that I have read about) like to be beaten with a stick or rolled on the ground, really level for operation, fooling the thermister, adding some type of additional air flow on the upper coils, don't forget checking your LP pressure and then hedging your bet with extra frozen foods transfered to the refer compartment.
What about the fuses? Some of the models have old style automotive glass type fuses on the lower circuit board. Probably a 3 or 5 amp fuse. I believe you take the outside panel off to get to it.